MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
8.7.9 CF_VPOS
COMMAND
COMMAND “CF_VPOS_%1”[CR]
%1
“064”--- +64
“063”--- +63
:
“002”--- +2
“001”--- +1
“000”---
±
0
“-01”--- -1
“-02”--- -2
:
“-63”--- -63
“-64”--- -64
Details
Set V Position. (Only valid when it is in the usual Power On state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.7.10 CF_HSCALE COMMAND
COMMAND
“CF_HSCALE_%1”[CR]
%1
The same as CF_VSCALE COMMAND
Details
Set H Scale.(Only valid when it is in the usual Power On state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.7.11 CF_HPOS COMMAND
COMMAND
“CF_HPOS_%1”[CR]
%1
The same as CF_VPOS COMMAND
Details
Set H Position (Only valid when it is in the usual Power On state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.8 Lamp Series COMMAND
8.8.1 CF_LAMPH
COMMAND
COMMAND “CF_LAMPH_%1”[CR]
%1
“RST”
Details
Reset total lamp running time. (Only valid when it is in the usual Power On
state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
Page 30 / 53