9.6 STATUS READ COMMAND FOR VIDEO
9.6.1 CR_SERSYS
COMMAND
COMMAND “CR_SERSYS”[CR]
Details
Select selected signal.
When Auto mode, it returns by auto-detect.
Only available when Input is video. (Unavailable when Input is computer.)
Acceptable
“000_%1”[CR]
%1
“1080I60”-- 1080i 60Hz
“1080I50”-- 1080i 50Hz
“1035I”------ 1035i
“720P”-------- 720p
“575P”-------- 575p
“480P”-------- 480p
“575I”-------- 575i(include composite signal such as PAL)
“480I”-------- 480i(include composite signal such as NTSC)
“NO
□
SIGNAL”--- When No Signal
Response
Unacceptable
“101”[CR] --
When
Input is PC series
“
?
”[CR]
9.7 STATUS READ COMMAND FOR INPUT
9.7.1 CR_INPUT
COMMAND
COMMAND
“CR_INPUT”[CR]
Details
Get selected INPUT No.
Acceptable
“000_%1”[CR]
%1
“1”-”4”
Response
Unacceptable “
?
”[CR]
9.7.2 CR_SOURCE
COMMAND
COMMAND “CR_SOURCE”[CR]
Details
Get selected Source
Acceptable
“000_%1”[CR]
%1
“DIGITAL”-- DVI inputs is selected
“ANALOG”---- Analog RGB is selected.
“SCART”------ Scart is selected.
“HDCP”-------- HDCP is selected.
“VIDEO”------ Video input is selected.
“S-VIDEO”-- S-Video is selected.
“YPBPR”------ Y/Pb/Pr input is selected.
Response
Unacceptable
“Error Code”[CR] -- Invalid
“
?
”[CR] ------------ When receives unclear Command
Page 43 / 53