MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
8.10.10
CF_P-MANETIME COMMAND
COMMAND “CF_P-MANETIME_%1”[CR]
%1
“01”-”30”-- Directly set the time by the minute
“UP”------------ Set the time 1 minute longer
“DN”------------ Set the time 1 minute shorter
Details
Set Power management time. (Only valid when it is in the usual Power On
state.)
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.11
CF_FANSPEED COMMAND
COMMAND
“CF_FANSPEED_%1”[CR]
%1
“
MAX
”------Select maximum speed
“
NOR
”------Select normal speed
Details
Change Fan Control speed.
Only valid when it is in the usual Power On
state.)
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.12
CF_KEYDIS COMMAND
COMMAND “CF_KEYDIS_%1”[CR]
%1
“N/A”
--- RC and KEY are available
“RC”
...Bar the use of RC
“KEY”
...Bar the use of KEY
Details
Set bar the use of RC/KEY. (Only valid when it is in the usual Power On
state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.13
CF_FDEFAULT COMMAND
COMMAND
“CF_FDEFAULT_%1”[CR]
%1
“RST”
Details
Set Factory Default. (Only valid when it is in the usual Power On state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
Page 35 / 53