MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
9.11.2 CR_DISP COMMAND
COMMAND “CR_DISP”[CR]
Details
Get Display setting status
Acceptable
“000_%1”[CR]
%1
“ON”----- Set Display
“OFF”--- Cancel Display
Response
Unacceptable “
?
”[CR]
9.11.3 CR_LOGO COMMAND
COMMAND “CR_LOGO”[CR]
Details
Get Logo setting status
Acceptable
“000_%1”[CR]
%1
“ON”----- Set Logo
“OFF”--- Cancel Logo
Response
Unacceptable “
?
”[CR]
9.11.4 CR_RCODE COMMAND
COMMAND “CR_RCODE”[CR]
Details
Get the selected code in Remote Control mode
Acceptable
“000_%1”[CR]
%1
“001”
=
Code1 is selected
“002”
=
Code2 is selected
Response
Unacceptable “
?
”[CR]
9.11.5 CR_LANG COMMAND
COMMAND “CR_LANG”[CR]
Details
Get selected language
Acceptable
“000_%1”[CR]
%1
“ENG”---- English is selected
“DEU”---- German is selected
“FRA”---- French is selected
“ITA”---- Italian is selected
“ESP”---- Spanish is selected
“POR”---- Portuguese is selected
“NED”---- Dutch is selected
“SVE”---- Swedish is selected
“JPN”---- Japanese is selected
“CHI”---- Korean is selected
“KOR”---- Chinese is selected
“RUS”---- Russian is selected
Response
Unacceptable “
?
”[CR]
Page 49 / 53