MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
8.8.2 CF_LAMPMODE
COMMAND
COMMAND “CF_LAMPMODE_%1”[CR]
%1
“NORMAL”-- Set lamp to normal mode
“ECO”-------- Set lamp to silent mode.
“AUTO”------ Set lamp to auto mode
Details
Select lamp mode. (Only valid when it is in the usual Power On state.)
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.9 Sound
Series
COMMAND
8.9.1 CF_VOLUME
COMMAND
COMMAND “CF_VOLUME_%1”[CR]
%1
“000-063”------ Directly set Volume value
“UP”---------------- Volume setting value +1.
“DN”---------------- Volume settigng value -1.
Details
Control Volume setting value. (Only valid when it is in the usual Power On
state.)
The same operation as a remote control’s turning up/down the volume.
Also, the command directly sets the volume value.
When setting volume value like remote control unit” operation, Sound Mute
ON will be canceled. The setting value will be stored in a projector.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.9.2 CF_MUTE
COMMAND
COMMAND “CF_MUTE_%1”[CR]
%1
“ON”------ set Sound Mute to ON
“OFF”---- set Sound Mute to OFF
Details
Control Sound Mute ON/OFF.(Only valid when it is in the usual Power On
state.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
Page 31 / 53