MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
available only when Input is Y, Pb/Cb, Pr/Cr.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.7 Screen Control Series COMMAND
8.7.1 CF_SCREEN
COMMAND
COMMAND
“CF_SCREEN_%1”[CR]
Input is
computer
“WIDE”
-------- Select 16:9
“TRUE”
-------- Select True size
“DZOOM UP”-- Zoom Out with Digital zoom
“DZOOM DN”-- Zoom in with Digital zoom
%1
Input is
Video Series
“NORMAL”
---- Select 4:3 screen
“WIDE”
-------- Select 16:9 screen
Details
Select screen size.(Only valid when it is in the usual Power ON state.)
When Input does not meet the requirement for the specified %1, the response
will be “101”[CR], and the command is not executed..
Note)”WIDE”/”NORMAL”is available when Input signal is 4:3. (This
command is not available when 16:9 wide signal.)
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.7.2 CF_FLSCREN
COMMAND
COMMAND
“CF_FLSCREEN_%1”[CR]
%1
“ON”------ Select Full Screen
“OFF”---- Cancel Full Screen
Input is
computer
Set/cancel Full Screen. (Only valid when it is in the usual
Power On state.)
The value set by this Command will not be saved to the
projector.
Therefore, when ALL OFF the projector, the value will
return to the original setting. (stay in Stand By mode.)
(stays in Stand By mode.)
Details
Input
が
Video Series
Invalid
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
Page 27 / 53