MR3P Series EXPAND SERIAL COMMAND FUNCTION SPECIFICATION
Software Engineer Division
9.5.4 CR_H-POS
COMMAND
COMMAND “CR_H-POS”[CR]
Details
Get Horizontal position value
Acceptable
“000_%1”[CR]
%1
“0000”-”nnnn”
(nnnn = Total Dots - Display Dots)
Response
Unacceptable
“Error Code”[CR] --- Invalid
“
?
”[CR] ------------- When receives unclear Command
9.5.5 CR_V-POS
COMMAND
COMMAND “CR_V-POS”[CR]
Details
Get Vertical position value.
Acceptable
“000_%1”[CR]
%1
“0000”-”nnnn”
(nnnn = Total Line - Display Line)
Response
Unacceptable
“Error Code”[CR] --- invalid
“
?
”[CR] ------------- When receives unclear Command
9.5.6 CR_DDOTS
COMMAND
COMMAND “CR_DDTOS”[CR]
Details
Get Display Dots value.
Acceptable
“000_%1”[CR]
%1
“0100”-”nnnn”
(nnnn = Total Dots – Horizontal Position)
Response
Unacceptable
“Error Code”[CR] --- Invalid
“
?
”[CR] ------------- When receives unclear Command
9.5.7 CR_DLINE
COMMAND
COMMAND
“CR_DLINE”[CR]
Details
Get Display Line value
Acceptable
“000_%1”[CR]
%1
“0100”-”nnnn”
(nnnn = Total Line – Vertical Position value
Response
Unacceptable
“Error Code”[CR] --- Invalid
“
?
”[CR] ------------- When receives unclear Command
Page 41 / 53