background image

Installation Instructions 

 

Lectric 2-C & 4-C 

FLUSH

 

CEILING

 

MOUNT

 

SCREEN

 

LARGE

 

SERIES

 

 
 

 

 
 
 
 
 
 

 
 
 
 
 
 
 

VIDEO PROJECTION SCREENS 

 

Summary of Contents for Lectric 2-C

Page 1: ...Installation Instructions Lectric 2 C 4 C FLUSH CEILING MOUNT SCREEN LARGE SERIES VIDEO PROJECTION SCREENS ...

Page 2: ...E INSTRUCTIONS ARE NOT FOLLOWED WARNING FAILURE TO READ THOROUGHLY UNDERSTAND AND FOLLOW ALL INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY DAMAGE TO EQUIPMENT OR VOIDING OF FACTORY WARRANTY IT IS THE INSTALLER S RESPONSIBILITY TO MAKE SURE ALL COMPONENTS ARE PROPERLY ASSEMBLED AND INSTALLED USING THE INSTRUCTIONS PROVIDED WARNING FAILURE TO INSTALL ELECTRICAL REQUIREMENTS ACCORDING TO NATIONA...

Page 3: ...EL 954 545 9006 FAX 954 545 9011 EMAIL info vutec com LECTRIC 2 C 4 C FLUSH CEILING MOUNT WITH SERVICE DOOR SELF SUPPORTED shown and TAB TENSIONED screens Figure 1 SCREEN TYPE LENGTH DIM A SELF SUPPORTED VIEWING WIDTH 15 1 2 7 3 4 TAB TENSIONED VIEWING WIDTH 22 1 2 11 1 4 ...

Page 4: ... CHECK WEIGHT DATA AT THE END OF THIS DOCUMENT Threaded rods of 3 8 10mm diameter hex nuts and helical lock washers are to be provided by installers After securing the housing in the ceiling check that the housing is level and plumb Make adjustments as necessary then tighten the hex nuts It is recommended that safety cables be added to the housing for additional safety concern The cables may be lo...

Page 5: ... SCREEN ROLLER ASSEMBLY REMOVAL Section for instructions CAUTION BE SURE TO PLACE THE CONNECTING WIRES INSIDE BEFORE PROCEEDING WITH THE HOUSING INSTALLATION Install the housing once the screen roller assembly is removed Be sure the housing is level and plumb Figure 2c Option 1 Suspended Mounting Figure 3 Option 2 Blind Pocket Mounting ...

Page 6: ...untie the door Remove the electrical cover to gain access to the electrical compartment Simply push up or using a screwdriver and make a light hit upward on the cover to pop open Figure 5a Pull down the Eurostrip to replace the pigtail with 4 conductor cable The cable should go to location where the wall switch is to be located Make connections to the wall switch Perform quick test by sending the ...

Page 7: ...X 954 545 9011 EMAIL info vutec com Figure 4b Electrical Connections 230 VAC The screen may also be operated by optional IR RF remote control optional 12VDC trigger relay optional Low Voltage control or optional Home Automation control by AMX Crestron etc Consult Vutec for further details ...

Page 8: ...ITCH Key features of the hex socket Figures 2a and 6 limit switch Each full turn 360 degrees of the hex socket cause the screen to travel approximately 3 4 inch Follow the label affixed to the electrical cover plate for turning of the hex sockets As the hex socket is turning the screen will move only in the direction of increasing travel Hint Going down direction lower limit will see the screen mo...

Page 9: ...e the desired lower limit proceed to MORE SCREEN DROP part to lower the screen to the desired lower limit Figure 6 Limit Switch Sockets PUSH BUTTON LIMIT SWITCH Depending on availability some screens might be equipped with motor with push button limit switches Key features of the push button limit switch Button popped out free running motor limit switch is not engaged Button pushed in motor limit ...

Page 10: ...9 06 26 2017 Rev B INSTL L2 C_L4 C B VUTEC CORPORATION www vutec com TEL 954 545 9006 FAX 954 545 9011 EMAIL info vutec com SCHEMATIC 120 VAC Installations 230 VAC Installations ...

Page 11: ...tor hums a Check breaker fuse b Check wall switch c Push button limit switches might be tripped d Thermal overload tripped e Defective motor or wall switch f Temporary binding g Capacitor burned out a Replace blown fuse b Check wall switch connections Bypassing wall switch as a test c See Electrical to reset push button limit switch Reset White button for upper limit d Let motor cool down for 15 m...

Reviews: