ENCLOSURE 2 FLAG LETTER DEFINITIONS
®
making
since 1986
water work
T
Normal Stop Time
During normally scheduled programmed irrigation, we
crossed the
HOLD OVER
time. The irrigation was
terminated and the remaining time was added to the hold-over
for that station. This flag is set during manually scheduled
hold-over if during that activity we hit the manual hold-over
STOP TIME
.
F Controller
Off
The normally scheduled programmed irrigation did not apply
any time for this station because the controller was set to
OFF
. This flag will be set if the controller is turned
OFF
in
the middle of applying normally scheduled irrigation or
scheduled manual hold-over.
M
Moisture Sensor
Caused Cycle Skip
The
MOISTURE SENSOR
caused he programmed irrigation
or scheduled hold-over time to be cut short. A number of
cycles did not irrigate because the moisture sensor reading
was equal to or above the set point. Anywhere from one cycle
to all of the scheduled cycles may be curtailed. This flag is set
in the master station as well as all of his slaves.
X
Moisture Sensor
Max water Days Set
While using moisture sensing,
MAX WATER
was set
causing this station to irrigate all of its normally scheduled
irrigation- regardless of what the moisture sensor said to do.
V
Master Valve
Override
The master valve was closed using
MASTER VALVE
OVERRIDE.
This master valve closure either prohibited the
normally scheduled irrigation from occurring or it interrupted
it. This flag will be set if the master valve is closed using
master valve override during scheduled manual hold-over.
Flag Letter Definitions
For Moisture sensors
LETTER DESCRIPTION
DEFINITION
---
Reading Never Taken
This means the “Moisture sensor in use block” in Program Data is
checked but the program in the “Use Moisture Sensor in the
following program” block using this station is not checked for
moisture sensor usage.
R**
Reading Out Of Range
This means the reading the controller received from the Moisture
Sensor was out of the realm of 0-100 therefore out of range.
F** No
Filtered
Reading
Hardware problem with the controller / moisture sensor / or field
wiring
S**
Signal Never went Away
Hardware problem with the controller.
O--
Reading Not Put In Line
Yet
This means that there is a Moisture Sensor assigned to this station
via a program, but has not yet taken a reading.