SECTION 4 FLOW
making
since 1986
water work
The LEARN THE EXPECTED FLOW RATES screen
is displayed (Figure 4.7).
PROG A . . . . . . . . . . . . . . . . . . . . . . . NO
DRIP 1 . . . . . . . . . . . . . . . . . . . . . . . NO
DRIP 2 . . . . . . . . . . . . . . . . . . . . . . . NO
PROG B . . . . . . . . . . . . . . . . . . . . . . . NO
PROG C . . . . . . . . . . . . . . . . . . . . . . . NO
PROG D . . . . . . . . . . . . . . . . . . . . . . . NO
PROG E . . . . . . . . . . . . . . . . . . . . . . . NO
to set the expected flow rate.
Learn The Expected Flow Rates for:
LEARN THE EXPECTED FLOW RATES
each station and use the measured flow
At the next program start , turn on
Figure 4.7
•
LEARN EXPECTEDS:
This allows you to
learn the expected flow rate for each station at
the next program start. Once the flow rate has
been recorded the entry on the screen will
default back to NO.
2.
Press the
PLUS
or
MINUS
keys to
select the program.
3.
Press the blue
ARROW
keys to
change the setting.
THIS CONCLUDES THE FLOW METER
SECTION
B. LINE FILL & VALVE CLOSE TIMES
The Line Fill & Valve Close times are used to allow
each valve time to stabilize before checking flow.
After you have enabled the flow meter on the FLOW
METER screen as described on the previous page:
1.
Press the
BACK
key twice to return
to the FLOW METER, MASTER
VALVE, & PUMP screen (Figure 4.1).
2.
Press the
LINE FILL & VALVE
CLOSE TIMES
Menu key.
The LINE FILL & VALVE CLOSE TIMES screen is
displayed (Figure 4.8).
PROG A . . . . . . . . . . . . . . 60 60
( times are in seconds )
PROG D . . . . . . . . . . . . . . 60 60
PROG E . . . . . . . . . . . . . . 60 60
DRIP 1 . . . . . . . . . . . . . 60 60
DRIP 2 . . . . . . . . . . . . . 60 60
Fill Close
PROG B . . . . . . . . . . . . . . 60 60
PROG C . . . . . . . . . . . . . . 60 60
LINE FILL & VALVE CLOSE TIMES
Line Valve
Figure 4.8
•
LINE FILL TIMES:
The delay time in seconds
that the controller will wait to check flow rates
on a station allowing the flow to stabilize.
•
VALVE CLOSE TIMES
: The delay time in
seconds that the controller will wait to check
flow on the very next valve allowing time for
the previous valve to close.
3.
Press the blue
ARROW
keys to move
the cursor to the PROG A LINE
FILL TIME.
4.
Press the
PLUS
or
MINUS
keys to
set the desired seconds.
Note:
Use this same method to change the VALVE
CLOSE TIME for program A and then repeat these
steps for each program on the list.
5.
Press the
BACK
key to return to
the FLOW METER, MASTER
VALVE, & PUMP SETUP screen
(Figure 4.9).
THIS CONCLUDES THE LINE FILL & VALVE
CLOSE TIMES SECTION