![Calsense 500 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/calsense/500-series/500-series_programming-manual_3519076016.webp)
SECTION 4 FLOW
®
making
since 1986
water work
2.
Press the blue
ARROW
keys to
move the cursor to the USE YOUR
OWN K & OFFSET setting, which is
set to NO as the default.
If using a FMBX flow meter see:
2.
FMBX flow meter setup
If using a regular flow meter see:
3. Regular flow meter setup
2. FMBX flow meter setup
If the flow meter installed on the system is a Calsense
FMBX, change the “Use your own K & Offset” to YES,
(The screen will appear as shown in Figure 4.4).
Is a Flow Meter in use ? YES
Use your own K & Offset ? YES
FLOW METER
METER 1
K: 10.000
automatically learned.)
Learn Expecteds
OFFSET: 0.200
(Expected Flow Rates can be
Figure 4.4
1.
Press the blue
ARROW
keys to
move the cursor to the K: setting.
2.
Press the
PLUS
or
MINUS
keys to
change the number.
3.
Press the blue
ARROW
keys to
move the cursor to the OFFSET:
setting.
4.
Press the
PLUS
or
MINUS
keys to
change the number.
Note:
The two settings that must be set are the K
value and the Offset. If you know these values enter
them now. If not, Call Calsense at 1-(800)-572-8608
for assistance.
3. Regular flow meter setup
If the answer to Use your own K & Offset is NO.
1.
Press the blue
ARROW
keys to move
the cursor to the SIZE setting.
2.
Press the
PLUS
or
MINUS
keys to
change the flow meter type.
Refer to the chart (Figure 4.5), to choose the correct
flow meter type.
MODEL NUMBER
SIZE
FM-1
FM-1B
FM-1.25B
FM-1.5
FM-2
FM-3
1” PLASTIC FLOW METER
1” BRASS FLOW METER
1 ¼” BRASS FLOW METER
1 ½” PLASTIC FLOW METER
2” PLASTIC FLOW METER
3” PLASTIC FLOW METER
Figure 4.5
4. Learn Expecteds (Flow rate)
The Learn Expecteds option on the controller will learn
the expected flow rate for each station on each
program selected.
1.
After you have entered the appropriate
Flow Meter(s) select the
LEARN
EXPECTEDS
Menu key (Figure 4.6).
Is a Flow Meter in use ? YES
automatically learned.)
Learn Expecteds
(Expected Flow Rates can be
METER 1
SIZE: FM-1
FLOW METER
Use your own K & Offset ? NO
Figure 4.6