8 MAINTENANCE

Before any operations it's necessary to disconnect the power
supply. 
If required ask to an electrician or to an expert technician.

Every maintenance operations, cleaning or reparation
executed  with  the  electrical  system  under  voltage,  it
could cause serious injuries to people.

In case of extraordinary maintenance, or maintenance opera-
tions that require part-removing, the operator must be a quali-
fied technician able to read schemes and drawings.
It is suggest to  register all maintenance operation executed. 

During maintenance keep particular attention in order
to avoid the introduction of small external parts, that
could compromise the device safety.

It  is  forbidden  to  execute  any  operations  with  the
direct  use  of  hands.  Use  water-resistant,  anti-cut
gloves to disassemble and clean the filter or in other
particular cases.
During maintenance operations external personnel is
not allowed.

Maintenance operations that are not described in this manual
must  be  made  only  by  special  personnel  authorized  by
Calpeda S.p.A.

For  further  technical  information  regarding  the  use  or  the
maintenance of the device, contact Calpeda S.p.A.

9. DISPOSAL

The final disposal of the device must be done by specialized
company.
Make sure the specialized company follows the classification
of the material parts for the separation. 
Observe  the  local  regulations  and  dispose  the  device  accor-
dingly with the international rules for environment protection.

10 SPARE PARTS
10.1 Spare-parts request

When  ordering  spare  parts,  please  quote  their  designation,
position number in the cross section drawing and rated data
from the pump name plate (type, date and serial number).

The spare parts request shall be sent to CALPEDA S.p.A. by
phone, fax, e-mail.

Changes reserved.

OFF

i

i

GB

CS-R Rev. 2 - Operating Instructions

Pagina 9 / 48

11. Troubleshooting

WARNING:

Turn off the power supply before performing any operations.

Do not allow the pump or motor to run  when dry even for a short period
Strictly follow the user instructions and if necessary contact an authorised service centre

OFF

PROBLEMS

1) The motor does

not start

2) Fuses burn at

starting 

3) The overload rely

cuts in after a few
seconds of ope-
ration.

4) The overload rely

cuts in after a few
minutes of opera-
tion.

5) The differential

relay cuts in

PROBABLE CAUSE

a) The selector switch is at OFF
b) The motor is not being powered 
c) The  automatic  control  devices  (the  level

switch, etc.) do not give consent

a) Unsuitable fuses
b) Locked rotor
c) Power  cable  or  connection  no  longer  intact

(in short-circuit)

a) The  nominal  voltage  does  not  reach  all  the

motor phases.

b) The current consumption is unbalanced with

at  least  one  phase  having  current  greater
than the nominal one.

c) The current consumption is anomalous
d) Incorrect relay calibration
e) Locked rotor.
f) The  power  supply  voltage  does  not

correspond to that of the motor.

a) Incorrect relay setting
b) The power supply network voltage is too low
c) The  current  consumption  is  unbalanced  at

the  phases  with  one  phase  higher  than  the
nominal power.

d) The pump does not rotate freely because of

some friction points.

e) The pump does not rotate freely because of

the high concentration of sand.

f) The unit is covered with sand.
g) High power panel temperature

a) Insufficient electrical insulation.

POSSIBLE SOLUTIONS

a) Select ON
b) Check if some fuses are burnt or if the protective relay has cut

in. Check terminal tightness. Check if power is being supplied

c) Wait  for  the  operation  conditions  to  return  or  verify  automatism

efficiency

a) Replace with fuses that are suitable for motor absorption.
b) Send the motor to the authorized service centre.
c) Replace the cable and repeat the connection.

a) Check the integrity of the electrical equipment.

Check the tightness of the terminal block.
Check the power supply voltage.

b) Check  the  imbalance  at  the  phases  as  described  in  paragraph

5.5  ‘Connection  and  electrical  information’.  If  necessary  send
the motor to the authorized service centre

c) Verify the accuracy of the star or delta connections.
d) Check if the amperage setting is correct.
e) Send to the authorized service centre
f) Replace the motor, or change the power supply.

a) See 3.d.
b) Contact the supplier.
c) See 3.b.
d) Send the unit to the authorized service centre.
e) Reduce the flow with the shutter.
f) Lower the well or raise the unit in a suitable manner. 
g) Make sure the relay is at room temperature. Protect the power

panel from sun and heat.

a) Check the insulation resistance with a megohmmeter according

to  the  limits  given  in  the  section  “Electrical  connections”.  If
necessary send the motor to the authorized service centre

IST CSR 09_16 Rev2_MXS 11_03con gall  07/11/16  08:37  Pagina 9

Содержание CS-R Series

Страница 1: ...L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 6 English BETRIEBSANLEITUNG Seite 10 Deutsch INSTRUCTIONS POUR L UTILISATION Page 14 Fran ais INSTRUCCIONES DE USO P gina 18 Espa ol DRIFT INSTALLA...

Страница 2: ...e e indirizzo del Fabbricante Ragione sociale Calpeda S p A Indirizzo Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 Operatori autorizzati Il prodotto rivolto a oper...

Страница 3: ...aordinaria in cui si prevedere di togliere il filtro previsto l uso dei guanti per la protezione delle mani Segnale DPI obbligatori PROTEZIONE DELLE MANI guanti per la protezione da rischio chimico te...

Страница 4: ...proteggere la pompa contro il funzionamento a secco instal lare sonde di livello 6 6 1 Giunzione cavi Scegliere un adeguato cavo di alimentazione in base a potenza distanza caduta di tensione e tempe...

Страница 5: ...di sovrac carico scatta dopo alcuni minuti di fun zionamento 5 Scatta il rel dif ferenziale PROBABILI CAUSE a L interruttore di selezione si trova sulla posizione OFF b Il motore non viene alimentato...

Страница 6: ...facturer name and address Manufacturer name Calpeda S p A Address Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 Authorized operators The product is intended for use...

Страница 7: ...ventions where it is required to remove the filter safety gloves are required Signal individual protection device HAND PROTECTION gloves for protection against chemical thermal and mechanical risks 5...

Страница 8: ...voltage drop and temperature For connection of cables in the well use thermo shrinking insulation sheathes or other systems used for submerged cables Before lowering the motor into the well use approp...

Страница 9: ...inutes of opera tion 5 The differential relay cuts in PROBABLE CAUSE a The selector switch is at OFF b The motor is not being powered c The automatic control devices the level switch etc do not give c...

Страница 10: ...eim eingeschalteten Ger t vorzunehmen sind 1 2 Firmenbezeichnung und Adresse vom Hersteller irmenbezeichnung Calpeda S p A Adresse Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italien www c...

Страница 11: ...mm Obligatorische PSA HANDSCHUTZ Schutzhandschuhe zum Schutz vor chemi schen thermischen und mechanischen Risiken 5 LAGERUNG UND UMSCHLAG Das Produkt ist verpackt damit der Inhalt nicht besch digt wir...

Страница 12: ...dung im Brunnen w rmeverengende Isoloierhu lsen oder andere Systeme fu r Unterwasser Kabel verwenden Vor dem Absenken des Motors in den Brunnen ist mit Instrumenten die Kontinuit tsmessung zwischen de...

Страница 13: ...ieb in Kraft 5 Das Differentialrelais l st sich aus M gliche Ursachen a Der W hlschalter befindet sich in Position OFF b Der Motor wird nicht gespeist c Die automatischen Kontrollvorrichtungen Niveaus...

Страница 14: ...iale Calpeda S p A Adresse Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italie www calpeda it 1 3 Op rateurs autoris s Le produit s adresse des op rateurs experts qui se parta gent entre ut...

Страница 15: ...els sont les dispositifs appropri s au travail r aliser Lors des op rations de maintenance ordinaire et extraordinaire o il faut enlever le filtre l utilisation des gants pour la protection des mains...

Страница 16: ...e d alimentation appropri en fonction de la puissance de la distance de la chute de tension et de la temp rature Pour la jonction des c bles du puits utiliser des gaines ther mor tractables sp ciales...

Страница 17: ...clen che apr s peu de minutes de fonc tionnement 5 Le relais diff ren tiel se d clenche CAUSES PROBABLES a Le sectionneur est en position OFF b Le moteur n est pas aliment c Les dispositifs de contr l...

Страница 18: ...on el dispositivo encendido 1 2 Nombre y direcci n del Fabricante Nombre Calpeda S p A Direcci n Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 Operadores autorizado...

Страница 19: ...ajos descritos En las operaciones de mantenimiento ordinario y extraordinario en que se va a quitar el filtro se prev el uso de guantes para la protecci n de las manos Se ales DPI necesarias PROTECCI...

Страница 20: ...stalar sondas de nivel 6 6 1 Uni n con cables Elija un cable de alimentaci n adecuado seg n la potencia distancia ca da de presi n y temperatura Para la uni n de los cables en el pozo use las vainas t...

Страница 21: ...segundos de funciona miento 4 El rel de sobrecarga se acciona despu s de unos minutos de funciona miento 5 El rel diferen cial se acciona CAUSAS PROBABLES a El interruptor de selecci n est en la posic...

Страница 22: ...gsnamn och tillverkarens adress F retagsnamn Calpeda S p A Adress Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italien www calpeda it 1 3 Auktoriserade operat rer Produkten r avsedd att anv...

Страница 23: ...tt anv nda under installations start och underh llsfaserna Skyddshandskar ska anv ndas under l pande och s rskilt underh ll n r filtret ska avl gsnas M rke Obligatorisk personlig skyddsutrustning SKYD...

Страница 24: ...lama m ste v ljas med h nsyn till effekt l ngd sp nningsfall samt temperatur F r anslutning av kablarna i borrh let skall krympslang eller annan skarvanordning anv ndas avsett f r dr nkbara pum par F...

Страница 25: ...el et utl ses efter ett par minuters funktion 5 Differentialrel et utl ses M JLIGA ORSAKER 1 V ljarbrytaren st r i l ge AV b Motorn f rs rjs inte c De automatiska kontrollanordningarna niv brytare osv...

Страница 26: ...ngrepen die uitgevoerd moeten worden nadat de machine uitgeschakeld en losgekoppeld is van de energiebronnen Ingrepen die uitgevoerd moeten worden terwijl de machine ingeschakeld is 1 2 Handelsnaam en...

Страница 27: ...s met zich mee 4 4 Veiligheids en informatietekens Voor dit type product zijn geen tekens op het product voorzien 4 5 Persoonlijke beschermingsmiddelen PBM In de fasen van installatie inschakeling en...

Страница 28: ...ermingsmechanisme dat het toevoersys teem scheidt in het geval van defecten richting aarde van de elektrische pomp Beveilig de pomp tegen droogdraaien d m v elektrocodes 6 1 1 Bevestiging van de kabel...

Страница 29: ...EN 1 De motor gaat niet aan 2 De zekeringen branden door bij het inschakelen 3 Het overbela stingrelais treedt na enke le seconden functioneren in werking 4 Het overbela stingrelais treedt na enke le...

Страница 30: ...1 5 1 5 Calpeda S p A 1 2 2 CS R 70 30 Dowcal N DowChemical CEE 6 2 2 1 Motor Max Cooling Max Liquid minimum starts P2 temperature flow velocity per hour 6CS R 4 11 kW 30 C 0 1 m s 15 13 15 kW 30 C 0...

Страница 31: ...50 380 44 50 400 42 50 415 42 60 21 3 460 40 2 60 18 5 460 36 1 60 18 5 380 41 3 3 D IP68 S1 IEC 60034 1 Max Thurst Load 30000N Serial Cos No 2015538127 N min 1 0 85 2830 2840 0 82 0 77 2855 0 845 34...

Страница 32: ...t dry running 6 6 1 a 6 7 30 Hz inverter PVC HT dV dt 500 V s Vpp 1 1400V PE2 PA dV dt 650 V s Vpp 1 1800V 1 T drive 6 8 soft starter SOFT STARTER soft starter 6 9 PT100 PT100 2 3 C 6 C 15 20 C 2 PVC...

Страница 33: ...CALPEDA SpA CALPEDA SpA 9 10 10 1 CALPEDA S p A i i OFF 11 OFF 1 2 3 4 5 OFF a b c a b c d e f a b c d d f g a ON a b c a b 5 5 c d e f a 3 d b c 3 b b e f g a IST CSR 09_16 Rev2_MXS 11_03con gall 07...

Страница 34: ...nza Italia www calpeda it 1 3 1 4 1 5 1 5 Calpeda S p A 1 2 2 CS R 70 30 Dowcal N DowChemical CEE 6 2 2 1 P2 6CS R 4 11 kW 30 C 0 1 m s 15 13 15 kW 30 C 0 2 m s 15 18 5 kW 25 C 0 2 m s 15 22 30 kW 25...

Страница 35: ...4 50 400 42 50 415 42 60 21 3 460 40 2 60 18 5 460 36 1 60 18 5 380 41 3 3 D IP68 S1 IEC 60034 1 Max Thurst Load 30000N Serial Cos No 2015538127 N min 1 0 85 2830 2840 0 82 0 77 2855 0 845 3430 0 81 3...

Страница 36: ...4 6 5 6 6 3 5 30 6 6 1 6 7 30 PVC HT dV dt 500 V s Vpp 1 1400V PE2 PA dV dt 650 V s Vpp 1 1800V 1 6 8 6 9 PT100 PT100 2 3 C 6 C 15 20 C 2 58 C PE2 PA 75 C 7 6 6 i OFF ON IST CSR 09_16 Rev2_MXS 11_03co...

Страница 37: ...S p A Calpeda S p A 9 10 10 1 Calpeda S p A i i OFF 11 OFF 1 2 3 4 5 a OFF b c a b c a b c d e f a b c d e f g a a ON b c a b c a b 5 5 c d e f a 3 d b c 3 b d e f g a IST CSR 09_16 Rev2_MXS 11_03con...

Страница 38: ...ntino Vicenza Italia www calpeda it 1 3 1 4 1 5 Calpeda S p A 1 2 2 CS R 70 30 N EEC 6 2 2 1 P2 6CS R 4 11 kW 30 C 0 1 m s 15 13 15 kW 30 C 0 2 m s 15 18 5 kW 25 C 0 2 m s 15 22 30 kW 25 C 0 2 m s 13...

Страница 39: ...400 42 50 415 42 60 21 3 460 40 2 60 18 5 460 36 1 60 18 5 380 41 3 3 D IP68 S1 IEC 60034 1 Max Thurst Load 30000N Serial Cos No 2015538127 N min 1 0 85 2830 2840 0 82 0 77 2855 0 845 3430 0 81 3455 0...

Страница 40: ...6 6 1 6 7 30HZ PVC HT dV dt 500 V s e Vpp 1 1400V PE2 PA dV dt 650 V s e Vpp 1 1800V 1 6 8 6 9 PT100 PT100 3 6 15 20 PVC 58 PE2 PA 75 7 6 6 8 CALPEDA CALPEDA S P A OFF ON i i i IST CSR 09_16 Rev2_MXS...

Страница 41: ...Rev 2 9 10 10 1 CALPEDA S P A OFF 11 OFF 1 2 3 4 5 a OFF b c a b c a b c d e f a b c d e f g a a ON b c a b c a b 5 5 c d e f a 3 d b c 3 b d e f g a IST CSR 09_16 Rev2_MXS 11_03con gall 07 11 16 08 3...

Страница 42: ...83 84 87 87 85 2825 2815 2830 2840 2835 2840 2855 2840 2820 2850 2845 2870 2860 3 3 2 4 1 4 5 2 5 5 5 4 4 5 5 3 5 3 6 5 1 1 5 1 5 2 1 7 2 5 2 6 1 95 2 5 1 7 2 2 2 4 2 30000 30000 30000 30000 30000 300...

Страница 43: ...05 2895 2905 60000 60000 60000 60000 60000 60000 60000 60000 8 NEMA 43 48 CS R Rev 2 12 1 Dimensioni e pesi Dimensions and weights Abmessung und Gewicht Dimensions et poids Dimensiones y pesos M tt oc...

Страница 44: ...44 48 CS R Rev 2 IST CSR 09_16 Rev2_MXS 11_03con gall 07 11 16 08 37 Pagina 44...

Страница 45: ...t Giunzione cavi Connection of cables Kabelverbindung Jonction des c bles Uni n de los cables Anslutning av kablar Bevestiging van de kabels grigio grey grau gris gris gr grijs marrone brown braun mar...

Страница 46: ...46 48 CS R Rev 2 IST CSR 09_16 Rev2_MXS 11_03con gall 07 11 16 08 37 Pagina 46...

Страница 47: ...EG Vorschriften 2006 42 EG 2014 30 EU 2014 35 EU entspre chen DECLARATION OF CONFORMITY KONFORMIT TSERKL RUNG DECLARATION DE CONFORMITE Nous Calpeda S p A d clarons que les moteurs 6CS R 8CS R 10CS R...

Страница 48: ...s p a Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia Tel 39 0444 476476 Fax 39 0444 476477 E mail info calpeda it www calpeda com IST CSR 09_16 Rev2_MXS 11_03con gall 07 11 16 08 37 Pa...

Отзывы: