Fabric OS Command Reference
73
53-1001764-01
bottleneckMon
2
bottleneckMon
Monitors and reports latency and congestion bottlenecks on F_Ports and E_Ports.
SYNOPSIS
bottleneckmon --enable
[
-cthresh
congestion_threshold
]
[
-lthresh
latency_threshold
] [-
time
seconds
]
[
-qtime
seconds
] [
-alert
|
-noalert
]
[
-lsubsectimethresh
time_threshold
]
[
-lsubsecsevthresh
severity_threshold
]
bottleneckmon --disable
bottleneckmon --config
[
-cthresh
congestion_threshold
]
[
-lthresh
latency_threshold
][
-time
seconds
]
[
-qtime
seconds
] [
-alert
|
-noalert
]
[
-lsubsectimethresh
time_threshold
]
[
-lsubsecsevthresh
severity_threshold
]
[[
slot
/]
port_list
]
bottleneckmon --configclear
[
slot
/]
port_list
bottleneckmon
--exclude
[
slot
/]
port_list
bottleneckmon --include
[
slot
/]
port_list
bottleneckmon
--show
[
-interval
seconds
] [
-span
seconds
]
[
-refresh
][
-congestion
|
-latency
] [[
slot
/]
port
| '*']
bottleneckmon --status
bottleneckmon --cfgcredittools -intport -recover
[
off
|
onLrOnly
|
onLrThresh
]
bottleneckmon--showcredittools
bottleneckmon --help
DESCRIPTION
Use this command to (1) detect latency and congestion bottlenecks on F[L]_Ports and E_Ports and (2) to
manage credit recovery on back-end ports. Bottleneck detection and credit recovery are two independent
functions; enabling credit recovery has no impact on bottleneck detection and vice versa.
Bottleneck Detection
For bottleneck detection, this command provides the following management functions:
•
Enabling or disabling bottleneck detection on a switch and optionally configuring thresholds and alert
parameters.
•
Changing alert parameters on specified ports after you have enabled the feature on the switch.
•
Configuring severity thresholds for congestion and latency bottlenecks for a switch or for a specified
port list.
•
Refining the criterion for defining latency bottleneck conditions to allow for more (or less) sensitive
monitoring at the sub-second level.
•
Clearing the configuration on specified ports only (this option cannot be performed switch-wide).
•
Excluding specified ports from being monitored or including previously excluded ports.
•
Generating history or status reports that show congestion bottlenecks and latency bottlenecks.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...