Fabric OS Command Reference
435
53-1001764-01
interfaceShow
2
helloTo
Hello timeout value, in milliseconds. When this timeout expires, a Hello frame is
sent to the neighbor switch through this port.
rXmitTo
Retransmission timeout value, in milliseconds. It is used to transmit topology
information to the neighbor switch. If no acknowledgement is received within this
value, the frame is retransmitted.
nCmdAcc
Total number of commands accepted from the neighbor switch. Number includes
Hellos, Link State Updates (LSUs), and LSAs.
nInvCmd
Number of invalid commands received from the neighbor switch. Usually
commands with an FSPF version number higher than the one running on the local
switch.
nHloIn
Number of Hello frames received from the neighbor switch.
nInvHlo
Number of invalid Hello frames (Hello frames with invalid parameters) received
from the neighbor switch.
nLsuIn
Number of LSUs received from the neighbor switch.
nLsaIn
Number of LSAs received from the neighbor switch.
attHloOut
Number of attempted transmissions of Hello frames to the neighbor switch.
nHloOut
Number of Hello frames transmitted to the neighbor switch.
attLsuOut
Number of attempted transmissions of LSUs to the neighbor switch.
nLsuOut
Number of LSUs transmitted to the neighbor switch.
attLsaOut
Number of attempted transmissions of LSAs to the neighbor switch.
nLsaOut
Number of LSAs transmitted to the neighbor switch.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
slot
For bladed systems only, specify the slot number of the port to be displayed,
followed by a slash (/).
port
Specify the number of the port to be displayed, relative to its slot for bladed
systems. Use
switchShow
for a list of valid ports. This operand is optional; if
omitted, the interface information for all ports is displayed.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...