584
Fabric OS Command Reference
53-1001764-01
perfTTmon
22
perfTTmon
Installs the Top Talker monitor in the specified mode.
SYNOPSIS
perfttmon
Port Mode:
perfttmon --add
egress | ingress [
slot
/]
port
perfttmon --show
[
slot
/]
port
[
number_of_flows
] [wwn| pid]
perfttmon --delete
[[
slot
/]
port
|
-all
|
-sconfig
]
Fabric Mode:
perfttmon --add fabricmode
perfttmon --show dom
domain id
[
number_of_flows
] [wwn| pid]
perfttmon --delete fabricmode
perfttmon --help
DESCRIPTION
Use this command to install the Top Talker monitor. The Top Talker feature provides real-time information
about the top 'n' bandwidth consuming flows from a set of a large number of flows passing through a
specific point in the network (after initial stabilization).
Top Talkers can display between 1 and 32 flows depending on hardware platform. The maximum flows
displayed are as follows:
32
For the Brocade 300, 5100, 5300, 6510, 8000 (FC Ports only) FC8-xx, and
FC16-xx port blades.
16
For the Brocade 5000.
Top Talker supports the following two modes,
Port Mode
and
Fabric Mode
:
•
In
Port Mode
, Top Talker is installed at the port level to measure the traffic flowing through the port
to different destinations. The output displays the data in a sorted order based on the data rate of
each flow.
•
In
Fabric Mode
, Top Talker measures the top "n" bandwidth using flows on a given switch. Top
Talker installs only on E_Ports and measures the data rate of all the possible flows in the fabric. Flow
is a pair of communicating FC addresses (SID and DID). Top Talkers in Fabric Mode and EE
monitors are mutually exclusive. EE monitors must be removed from all switches before enabling
fabric mode.
NOTES
This command requires an Advanced Performance Monitor license.
Top Talkers are incompatible with Frame Redirection, and therefore this feature is not supported on the
Brocade Encryption switch for encrypted data traffic.
Top Talkers are not supported on embedded platforms.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...