Fabric OS Command Reference
71
53-1001764-01
bootLunCfg
2
bootLunCfg
Transparently configures the boot LUN for an HBA.
SYNOPSIS
bootluncfg --add
HBA_WWN PWWN LUN_ID
bootluncfg --delete
HBA_WWN
[
PWWN LUN_ID
]
bootluncfg --show
bootluncfg --help
DESCRIPTION
Use this command to configure the boot LUN for an HBA.
Existing fabric-based boot LUN discovery allows the host's boot LUN information to be stored in the
fabric zone database by using a zone name that contains the PWWN of an HBA port. The zone members
consist of storage target PWWN and LUN ID.
This command provides a simplified and transparent procedure for configuring the boot LUN. Once
configured, the HBA boot code queries the zone member list for the zone name matching the HBA
PWWN to determine the boot target and LUN.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
HBA_WWN
Specifies the WWN of the HBA port connecting to the boot LUN. This is a
hexadecimal number, for example, 10:00:00:000:05:1e:41:9a:cb.
PWWN
Specifies the WWN of the remote storage target's port. For example,
50:00:00:05:1e:41:9a:ca. This operand is required with the
--add
option and
optional with the
--delete
option.
LUN_ID
Specifies the hexadecimal LUN identification. The LUN ID is represented as an
eight-byte value (four-level LUN addressing), for example,
09AABBCCDDEEFF00. This operand is required with the
--add
option and
optional with the
--delete
option.
--add
Configures the specified HBA (HBA_WWN) to boot from the specified LUN
(LUN_WWN) accessible through the Target PWWN (PWWN).
--delete
Removes the mapping for the HBA (HBA_PWWN) to boot from the LUN (LUN_ID)
accessible through the Target Port (PWWN).
--show
Displays all configured HBA to Port/LUN Mappings.
--help
Displays the command usage.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...