Fabric OS Command Reference
731
53-1001764-01
portLedTest
2
1
Turn Port status LED off.
2
Turn Port status LED amber.
3
Turn Port status LED green.
16
Turn Port speed LED green.
17
Turn Port speed LED amber.
EXAMPLES
To test port LEDs:
switch:admin>
portledtest --slot 1 -ports 1/1-1/5
Running portledtest ..............
WARNING:
This test should NOT be aborted in the middle. If aborted, current
blade or the switch (in-case of Pizza box) may become unusable.
Reset the blade or the switch to recover.
PASSED.
To test port LEDs on a Brocade 8000 using default values:
switch:admin>
ceeportledtest
PASSED.