Fabric OS Command Reference
189
53-1001764-01
cryptoCfg
2
-
Tape policy type: pool-based or LUN-based
-
Key life: key lifespan in days
-
Volume/pool label
-
LUN state: Refer to the
Fabric OS Encryption Administrator's Guide
.
-
Encryption algorithm: AES256 -XTS (disk), AES256-CCM (tape), or none
-
Compression algorithm
-
Key ID state: available or not available
-
Key ID: numeric identifier if available
-
New LUN: Yes or No
-
Replication LUN type: Primary or Mirror
If the LUN is a disk and the LUN is enabled for auto rekey, the following additional information is
displayed below the Key ID. Refer to the example section for an illustration.
-
Key creation time: date and time
-
Key life: remaining time (in days) until the key expires
-
Rekey status: 0 = rekey in progress, 1 = no rekey in progress
-
Key expiration time: date and time
-
Time remaining to Auto Rekey: Displays key life for LUNs that
-
are currently being rekeyed and after the rekey is complete.
-
The remaining Key life period is displayed in the following format:
num_yrs
,
num_months
,
num_days
,
num_minutes
.
When used with
-cfg
the
--show -LUN
command displays LUN configuration information:
•
EE node: node WWN
•
EE slot: slot number
•
Target: target port WWN and node NWWN
•
VT: virtual target port WWN and node WWN
•
Number of hosts: numeric value
•
Configuration status: committed or defined
•
For each host:
-
Host port WWN and node WWN
-
Virtual initiator port WWN and node WWN
-
Virtual initiator PID
•
Number of LUNs
•
For each LUN:
-
LUN number: numeric identifier
-
LUN type: disk, tape drive, tape medium changer, tape attached medium changer,
offline/unknown, or unsupported/other
-
LUN status: numeric value
-
Encryption mode: encrypt or cleartext
-
Encryption format: native or DF compatible
-
Tape policy type: pool-based or LUN-based
-
Encrypt existing data: disabled or enabled
-
Rekey: disabled or enabled
-
Key ID state: Read, Write, or Key ID not applicable
-
Key life (in days): numeric value
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...