Fabric OS Command Reference
311
53-1001764-01
fcrLsanCount
2
fcrLsanCount
Displays or sets the maximum LSAN count.
SYNOPSIS
fcrlsancount
[
max_lsan_count
]
DESCRIPTION
Use this command to set or display the maximum number of LSAN zones that can be configured on the
edge fabric. By default, the maximum LSAN count is set to 3000, which is also the minimum. This
command allows you to create up to 5000 LSANs on your edge fabric, if needed to support additional
devices. The maximum number of supported LSAN devices is 10,000.
When executed without operand, this command displays the current LSAN zone limit.
This command assumes that all FCRs in the same LSAN fabric matrix or backbone have the same
maximum LSAN count defined in order to protect the FCRs from running into indefinite state. Asymmetric
LSAN configurations due to different maximum LSAN counts may lead to different devices being
imported on different FCRs.
Because the maximum number of LSANs is configured per switch, if there is a different maximum LSAN
count on the switches throughout the meta-SAN, the device import or export will not be identical on the
FCRs. You should therefore enter the same maximum LSAN count for all the FCR switches in the same
backbone that support this feature. Verify the configured maximum limit against the LSANs configured
using the
fcrResourceShow
command.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
max_lsan_count
Specifies the maximum LSAN count.
EXAMPLES
To display the current LSAN limit:
switch:admin>
fcrlsancount
LSAN Zone Limit: 3000
To increase the LSAN zone limit:
switch:admin>
fcrlsancount 5000
LSAN Zone Limit: 5000
SEE ALSO
fcrResourceShow
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...