Fabric OS Command Reference
673
53-1001764-01
portCfgNPort
2
portCfgNPort
Enables or disables N_Port functionality for an Access Gateway port.
SYNOPSIS
portcfgnport
[
slot
/]
port1
[
-port2
] [
mode
]
DESCRIPTION
Use this command to enable or disable N_Port functionality for an Access Gateway port or for a range of
ports. The enabled N_Ports automatically come online if they are connected to an enterprise fabric
switch that supports NPIV. When used without operands, this command displays the port configuration.
NOTES
NPIV capability must be enabled on the ports connected to the Access Gateway. By default, NPIV is
enabled. Use
portcfgnpivport --enable
to enable NPIV capability on a port, if it was previously disabled.
Note that enabling or disabling NPIV capability is no supported in Access Gateway mode.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following optional operands:
slot
Specifies the slot number, followed by a slash (/) on bladed systems.
port1
[
-port2
]
Specifies a single port or a range of ports to be configured as N_Ports, for
example, 3-9, or 2/10-15.
mode
Enables (1) or disables (0) N_Port functionality on the specified ports. The default
mode is 0 (disabled).
EXAMPLES
To enable N_Port functionality for a port:
switch:admin>
portcfgnport 8 1
To enable N_Port functionality for a set of ports in a specific range:
switch:admin>
portcfgnport 2-3 1
To display the N_Port configuration for all ports:
switch:admin>
portcfgnport
Ports 0 1 2 3 4 5 6 7 8 9 10 [...]
--------------------+--+--+--+--+--+--+--+--+--+--+--+- [...]
Locked N_Port .. .. ON ON .. .. .. .. ON .. .. [...]
switch:admin>
portcfgshow
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
----------------+--+--+--+--+---+--+--+--+---+--+--+--+---+--+--+---
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Fill Word(On Active)0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Fill Word(Current )0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Locked N_Port .. .. ON ON .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
(output truncated)
SEE ALSO
portCfgShow
,
ag
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...