150
Fabric OS Command Reference
53-1001764-01
configure
22
Portlog Events Enable/Disable Settings
These settings determine whether or not various types of port events are logged.
Each event type displayed on the screen is enabled by default ("on"). When disabled, this event is not
logged by the port log.
Application Attributes
A number of application attributes are configurable. The following table specifies the attributes for
applications that can be modified.
Application Field Type Default Range
_______________________________________________________________
ssl
Certificate File string [not-set] varies
CA Certificate File string [not-set] varies
Length of crypto key number [128] 40,56,128
rpcd
Secure RPCd Callback
Secret string none varies
Webtools
Basic User Enabled boolean no no/yes
Perform License
Checking and Warning boolean yes yes/no
Allow Fabric Event
Collection boolean yes yes/no
Login Session Timeout number 200 60 to
(in seconds) 432000
NOTES
The maximum per port login limit is no longer configurable with this command. Use the
portcfgNPIVPort
--setloginlimit
command to configure this parameter on a per port basis.
The Telnet interface is no longer configurable with this command. Use the
ipFilter
command to enable or
disable the Telnet interface.
The SNMP attributes are no longer configurable with this command. Use the
snmpConfig --set seclevel
command to configure SNMP attributes.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To enable XISL use on a logical switch with FID 20:
switch:admin>
setcontext 20
switch:admin>
switchdisable
switch:admin>
configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [1]
Enable a 256 Area Limit
(0 = No,
1 = Zero Based Area Assignment,
2 = Port Based Area Assignment): (0..2) [0]
1
WWN Based persistent PID (yes, y, no, n): [no]
Allow XISL Use (yes, y, no, n): [yes]
yes
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...