Fabric OS Command Reference
35
53-1001764-01
ag
2
To remove the port group with
pgid
2:
switch:admin>
ag --pgremove 2
Port Group 2 has been removed successfully
switch:admin>
ag --pgshow
PG_ID PG_Name PG_Mode N_Ports F_Ports
-----------------------------------------------
0 pg0 lb,mfnm 0;2 4;5;6
3 FirstFabric lb 1;3 10;11
-----------------------------------------------
To enable managed fabric name monitoring in port group 3:
switch:admin>
ag --pgsetmodes 3 "mfnm"
Managed Fabric Name Monitoring mode has been \
enabled for Port Group 3
switch:admin>
ag --pgshow
PG_ID PG_Name PG_Mode N_Ports F_Ports
-----------------------------------------------
0 pg0 lb,mfnm 0;2 4;5;6
3 FirstFabric lb,mfnm 1;3 10;11
-----------------------------------------------
To disable managed fabric name monitoring in port group 3:
switch:admin>
ag --pgdelmodes 3 "mfnm"
Managed Fabric Name Monitoring mode has been disabled for Port Group 3
switch:admin>
ag --pgshow
-----------------------------------------------
0 pg0 lb,mfnm 0;2 4;5;6
3 FirstFabric lb 1;3 10;11
-----------------------------------------------
To get the current fabric name monitoring timeout value:
switch:admin>
ag --pgfnmtov
Fabric Name Monitoring TOV: 120 seconds
To set the fabric name monitoring timeout value to 30 seconds:
switch:admin>
ag --pgfnmtov 30
AG Preferred port information commands
To display preferred port settings for F_Ports:
switch:admin>
ag --prefshow
F_Ports Preferred N_Port
------------------------------------------
10;11 0
12;13 1
4;6 2
7;8;9 3
------------------------------------------
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...