Fabric OS Command Reference
929
53-1001764-01
slotShow
2
INITIALIZING
The blade is present, powered on, and initializing hardware components.
ENABLED
The blade is on and fully enabled.
DISABLED
The blade is powered on but disabled.
FAULTY
The blade is faulty because an error was detected.
UNKNOWN
The blade is inserted but its state cannot be determined.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
In a DCX-4S, slot 5 is occupied by a control processor blade (Blade ID 50). On a DCX, slot 5 is occupied
by the core blade (Blade ID 52).
OPERANDS
This command supports the following operands:
-p
In addition to the basic slot status view, displays the following information about
power consumption:
•
Total direct current (DC) power consumption for the chassis and individual
values for each blade (in Watts). Usage for other components is included but
not listed. Note that the data displayed in the "DC Power Consumption"
column and in the summary field "Total DC Power consumption" indicate the
maximum allowed power consumption, not a real-time value. Real-time
power consumption data is displayed for 16G platforms only with the
chassisShow
command.
•
Total alternating current (AC) power consumption in Watts.
•
AC efficiency, as a percentage of total and BTU.
•
Power efficiency in Watts/port and Watts/Gb.
-m
In addition to the basic slot status view, displays the Brocade model name for
each blade.
EXAMPLES
To display the status of all slots on a DCX 8510-8:
switch:user>
slotshow
Slot Blade Type ID Status
---------------------------------
1 SW BLADE 97 ENABLED
2 SW BLADE 96 ENABLED
3 SW BLADE 97 ENABLED
4 SW BLADE 96 ENABLED
5 CORE BLADE 98 ENABLED
6 CP BLADE 50 ENABLED
7 CP BLADE 50 ENABLED
8 CORE BLADE 98 ENABLED
9 SW BLADE 125 ENABLED
10 SW BLADE 126 ENABLED
11 SW BLADE 37 ENABLED
12 SW BLADE 55 ENABLED
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...