114
Fabric OS Command Reference
53-1001764-01
chassisEnable
22
chassisEnable
Enables all user ports in a chassis.
SYNOPSIS
chassisenable
DESCRIPTION
Use this command to enable a Virtual Fabric-aware chassis. All Fibre Channel ports that passed the
power-on self test (POST) are enabled. They may come online if connected to a device, or remain offline
if disconnected. Use
chassisEnable
to re-enable the chassis after making configuration changes or
running offline diagnostics.
If the chassis is partitioned into multiple logical switches and physically connected to multiple logical
fabrics, the logical switches rejoin their fabrics.
As each port is enabled, the front panel LED changes from slow-flashing amber to nonflashing green for
online ports, or to nonflashing amber for ports that do not initialize. Disconnected ports remain unlit.
Loopback ports slowly flash green when online.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To enable a chassis:
switch:admin>
chassisenable
SEE ALSO
bladeDisable
,
bladeEnable
,
chassisDisable
,
switchShow
,
switchDisable
,
switchEnable
,
switchCfgPersistentEnable
,
switchCfgPersistentDisable
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...