390
Fabric OS Command Reference
53-1001764-01
fwAlarmsFilterSet
22
fwAlarmsFilterSet
Enables or disables alarms for Fabric Watch.
SYNOPSIS
fwalarmsfilterset
[
mode
]
DESCRIPTION
Use this command to configure alarm filtering for Fabric Watch. By turning off the alarms, all
nonenvironment class alarms are suppressed. By turning on the alarms, all class alarms are generated.
NOTES
This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operand:
mode
Specify 1 to enable the alarms, 0 to disable the alarms. If no operand is specified,
the default value is 0 (alarms deactivated). This operand is optional; if omitted, this
command disables the alarms.
EXAMPLES
To enable alarms in Fabric Watch:
switch:admin>
fwalarmsfilterset
FW: Alarms are already disabled
switch:admin>
fwalarmsfilterset 1
FW: Alarms are already enabled
SEE ALSO
fwAlarmsFilterShow
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...