Fabric OS Command Reference
499
53-1001764-01
linkCost
2
1/7 500
1/8 500
1/9 (E_PORT) 500
1/10 500
1/11 500
1/12 500
1/13 500
1/14 500
1/15 500
Type <CR> to continue, Q<CR> to stop:
To set the ISL cost on a port:
switch:admin>
linkcost 1/9 1000
To display the new cost value on the same port:
switch:admin>
linkcost 1/9
Interface1/9 (E_PORT) Cost 1000 (STATIC)
To delete the cost value and reset to default:
switch:admin>
linkcost 1/9 0
To display the change:
switch:admin>
linkcost 1/9
Interface1/9 (E_PORT) Cost 500
To set the ISL cost to a value outside of the recommended range:
switch:admin>
linkcost 1/9 32766
The link cost entered may prevent some parts of the fabric
from being accessible. If you do not want this to happen, choose n|no
and run 'linkcost' again with a value lower than 32766.
Do you want to continue? (yes, y, no, n): [no]
y
switch:admin>
linkcost 1/9
Interface1/9 (E_PORT) Cost 32766 (STATIC)
To set the ISL cost to the maximum value:
switch:admin>
linkcost 1/9 65535
The link cost entered will cause the port to become unusable.
If you do not want this to happen, choose n|no
and run 'linkcost' again with a value lower than 65535.
Do you want to continue? (yes, y, no, n): [no]
n
SEE ALSO
interfaceShow
,
lsDbShow
,
topologyShow
,
uRouteShow
,
fcrRouterPortCost
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...