
Fabric OS Command Reference
685
53-1001764-01
portCfgShow
2
Fill Word (Current)
Displays the currently effective fill word setting. Possible values are 0(Idle-Idle),
1(arbff-arbff), 2(Idle-arbff), or 3(A-A then SW I-A).This parameter is set by the
portcfgFillword
command.
AL_PA Offset 13
Displays (..) or OFF when the arbitrated loop physical address (AL_PA) on the
port is configured to use a 0x0 AL_PA address (default). Displays ON when the
address configuration is 0x13 AL_PA. This value is set by the
portCfgAlpa
command.
Trunk Port
Displays ON when port is set for trunking. Displays (..) or OFF when trunking is
disabled on the port. This value is set by the
portCfgTrunkPort
command.
Long Distance
Displays (..) or OFF when long distance mode is off; otherwise, displays long
distance levels. This value is set by the
portCfgLongDistance
command. Values
are as follows:
LE
The link is up to 10 km.
LM
The link is up to 25 km.
L1
The link is up to 50 km.
L2
The link is up to 100 km.
LD
The distance is determined dynamically.
LS
The distance is determined statically by user input.
VC Link Init
Displays (..) or OFF when the long distance link initialization option is turned off.
Displays ON when it is turned on for long distance mode. This value is set by the
portCfgLongDistance
command.
Locked L_Port
Displays ON when the port is locked to L_Port only. Displays (..) or OFF when
L_Port lock mode is disabled and the port behaves as a U_Port). This value is set
by the
portCfgLport
command.
Locked G_Port
Displays ON when the port is locked to G_Port only. Displays (..) or OFF when
G_Port lock mode is disabled and the port behaves as a U_Port. This value is set
by the
portCfgGport
command.
Disabled E_Port
Displays ON when the port is not allowed to be an E_Port. Displays (..) or OFF
when the port is allowed to function as an E_Port. This value is set by the
portCfgEport
command.
ISL R_RDY Mode
Displays ON when ISL R_RDY mode is enabled on the port. Displays (..) or OFF
when ISL R_RDY mode is disabled. This value is set by the
portCfgISLMode
command.
Содержание Fabric OS v7.0.1
Страница 1: ...53 1002447 01 15 December 2011 Fabric OS Command Reference Supporting Fabric OS v7 0 1 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002447 01 ...
Страница 30: ...4 Fabric OS Command Reference 53 1002447 01 Using the command line interface 1 ...
Страница 118: ...92 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 270: ...244 Fabric OS Command Reference 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...
Страница 1132: ...1106 Fabric OS Command Reference 53 1002447 01 General Fabric OS commands and permissions A ...