CHAPTER 4: Base-Unit Installation
37
4.6 Identify the Module Locations and
Channel Numbers
M
ODULE
L
OCATION AND
N
OMENCLATURE
There are five chassis positions available for
modules in the Multiserver 5000. These are
identified from bottom to top as module locations
A through E.
• The Communications Control Module (CCM) is
always in module location A.
• A space is reserved below the CCM for the
optional NMS module. Its module location
is “$.” Note that there is no “$” printed on the
rear-panel of the Multiserver 5000.
• Optional modules can fill module locations B
through E.
C
HANNEL
L
OCATION AND
N
OMENCLATURE
Channel numbers are assigned to all the ports on
Table 4-1. CCM Indicator LEDs
INDICATOR STATUS
EQUIPMENT STATUS
AT
BO
A6
A5
A4
A3
A2
A1
1
0
X
X
X
X
X
X
1
Normal equipment status
0
0
1
0
0
0
0
0
ROM Test Failure (CommPak cartridge
failure)
0
0
0
0
0
0
0
1
CMOS Failure
2
0
0
0
0
0
0
1
0
Battery low
3
0
1
1
0
0
0
0
0
RAM Failure in CommPak cartridge
1
0
1
0
1
0
1
0
Parity error
1
1
1
1
1
1
1
1
CommPak cartridge not installed
properly or defective Multiserver unit
0
1
0
0
0
0
0
0
RAM Test Failure (CCM)
KEY
0 = LED off
1 = LED on
X = LED can be off or on. This will change as the status of the port activity changes.
1
If A1 is configured as a link, it blinks on power-up with no established link. (The default setting is for A1 to be
configured as a link.)
2
System can still operate with CMOS failure. All configuration data has been lost in the affected CMOS section,
and default values have been supplied.
3
System can still operate with a low battery. Configuration data may be lost if the Multiserver loses power.