Chapter 5 Function parameter
29
P7-13
Decimal point
0
~
65535h
-
×
P7-14
Cumulative power-on
time
0
~
65535 degree
-
×
P8 Group Auxiliary Functions
function
code
Parameter Name
Setting Range
Default Prop
erty
P8-00
Jog running frequency
0.00Hz
~
Maximum frequency
2.00Hz
〇
P8-01
Jog acceleration time
0.0s
~
6500.0s
20.0s
〇
P8-02
Jog deceleration time
0.0s
~
6500.0s
20.0s
〇
P8-03
Acceleration time 2
0.0s
~
6500.0s
Model
depende
nt
〇
P8-04
Deceleration time 2
0.0s
~
6500.0s
Model
depende
nt
〇
P8-05
Acceleration time 3
0.0s
~
6500.0s
Model
depende
nt
〇
P8-06
Deceleration time 3
0.0s
~
6500.0s
Model
depende
nt
〇
P8-07
Acceleration time 4
0.0s
~
6500.0s
Model
depende
nt
〇
P8-08
Deceleration time 4
0.0s
~
6500.0s
Model
depende
nt
〇
P8-09
Jump frequency 1
0.00Hz
~
Maximum frequency
0.00Hz
〇
P8-10
Jump frequency 2
0.00Hz
~
Maximum frequency
0.00Hz
〇
P8-11
Jump frequency amplitude
0.00Hz
~
Maximum frequency
0.01Hz
〇
P8-12
Positive reversal dead time
0.0s
~
3000.0s
0.0s
〇
P8-13
Reverse control enable
0: Allow 1: Prohibit
0
〇
P8-14
The set frequency is lower
than the lower limit
frequency.
0: Run at the following frequency limit
1: stop
2: Zero speed operation
0
〇
P8-15
Droop control
0.00Hz
~
10.00Hz
0.00Hz
〇
P8-16
Set the cumulative power-
on arrival time
0h
~
65000h
0h
〇
P8-17
Set cumulative run arrival
time
0h
~
65000h
0h
〇
P8-18
Start protection selection
0: no protection 1: protection
0
〇