Chapter 6 P7 keypad and display
93
P7-10
Product ID
-
-
P7-11
Software version
number
-
-
P7-12
Load speed display
0: 0 decimal place 1:1 decimal place
2: 2 decimal places 3: 3 decimal places
Default
:
1
Used to set the number of decimal places for the load speed display. The
following example illustrates how the load speed is calculated:
If the load speed display coefficient P7-06 is 2.000, the load speed decimal point
P7-12 is 2 (2 decimal places), when the inverter running frequency is 40.00Hz, the
load speed is: 40.00*2.000 = 80.00 (2 decimal places) display)
If the inverter is in the stop state, the load speed is displayed as the speed
corresponding to the set frequency, that is, “set the load speed”. Taking the set
frequency 50.00Hz as an example, the load speed in the stop state is: 50.00*2.000 =
100.00 (2 decimal places are displayed)
P7-13
Cumulative power-
on time
0h
~
65535h
-
The cumulative power-on time of the inverter from the factory is displayed.
When this time reaches the set power-on time (P8-17), the output terminal (24) outputs
an ON signal.
P7-14
Cumulative power
consumption
0kW
~
65535
-
Displays the cumulative power consumption of the inverter
P8 Group Accessibility
P8-00
Jog running frequency
0.00Hz
~
Maximum frequency
Default
:
2.00Hz
P8-01
Jog acceleration time
0.0s
~
6500.0s
Default
:
20.0s
P8-02
Jog deceleration time
0.0s
~
6500.0s
Default
:
20.0s
Define the given frequency and acceleration/deceleration time of the inverter when
jogging. When jog running, the start mode is fixed to the direct start mode (P 6 - 0 0 = 0),
and the stop mode is fixed to the deceleration stop (P6-10 = 0).
P8-03
Acceleration time 2
0.0s
~
6500.0s
depend
P8-04
Deceleration time 2
0.0s
~
6500.0s
depend
P8-05
Acceleration time 3
0.0s
~
6500.0s
depend
P8-06
Deceleration time 3
0.0s
~
6500.0s
depend
P8-07
Acceleration time 4
0.0s
~
6500.0s
depend