92
Chapter 6 P7 keypad and display
P7-05
LED
shutdown
Display
parameter
7 6 5 4 3 2 1 0
设定频率
母线电压
X
输入状态
输出状态
AI1
电压
AI2
电压
AI3
电压
计数值
15 14 13 12 11 10 9 8
长度值
PLC
阶段
负载速度
PID
设定
PULSE
输 入 脉 冲
频率
保留
保留
保留
If you need to display the above parameters after stop, set
the same as P7-03.
。
Default
:
33
Display parameters are used to set the parameters that can be viewed when the inverter
is running or stopped.
The maximum number of status parameters that can be viewed is 32. According to the
P8-03~P7-05 parameter values, the status parameters to be displayed are selected. The
display order starts from the lowest bit of P7-03.
P7-06
Load speed display
factor
0.0001
~
6.5000
Default
:
1.0000
When the load speed needs to be displayed, the corresponding relationship between
the inverter output frequency and the load speed is adjusted by this parameter. Refer
to the description of P7-12 for the specific correspondence.
P7-07
Module heat sink
temperature
0.0
℃~
100.0
℃
-
The temperature of the inverter module IGBT is displayed. Different models of inverter
module IGBT over-temperature protection values are different
P7-09
Cumulative running
time
0h
~
65535h
-
Displays the cumulative running time of the drive. When the running time reaches the
setting P8-17, the terminal (12) outputs an ON signal.
Frequency setting
Bus voltage
X input statue
Output statue
AI 1 voltage
AI 2 voltage
AI 3 voltage
Count value
Length value
PLC stage
Overload speed
PID setting
Pulse input
Reserved
Reserved
Reserved