![Best Power 0.75G/1.5P-T4 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/best-power/0-75g-1-5p-t4/0-75g-1-5p-t4_manual_2740223037.webp)
Chapter 5 Function parameter
34
P9-44
Run time at the first
failure
-
-
×
P9-47
Fault protection action
selection 1
Unit’s
:
Motor overload
(
Err 11
)
0
:
free stop
1
:
Stop by stop mode
2
:
Keep running
Ten’s
:
Input phase loss (Err12) as above
Hundred’s
:
Output phase loss (Err13) as
above
Thousand’s
:
External fault (Err15) is the
same as above
Ten Thousand’s digits: communication
abnormality (Err16) is the same as above
00000
〇
P9-48
Fault protection action
selection 2
Unit’s digit
:
Encoder/PG card incorrect
(
Err20
)
0
:
free stop
1
:
Stop by stop mode
2
:
keep running
Ten’s digit
:
function code reading and
writing incorrect
(
Err21
)
0
:
free stop
1
:
stop by stop mode
Thousand’s digit
:
motor too hot
(
Err25
)
same as P9-47
Ten Thousand’s digit
:
Run time arrives
(Err26) with P9-47
00000
〇
P9-49
Fault protection action
selection 3
Unit’s
:
Custom Fault 1 (Err27) Same as
P9-47
Ten’s
:
Custom Fault 1 (Err27) Same as
P9-47
Hundred’s
:
Power-on time arrives (Err29)
with P9-47
Thousand’s
:
Offload (Err30)
0: Free parking
1: slow down parking
2: Deceleration to 7% of the rated
frequency, automatically return to the set
frequency when no load is lost
Ten Thousand’s digit
:
PID feedback loss
(Err31) with P9-47
00000
〇
P9-50
Fault protection action
selection 4
Unit’s
:
Speed deviation is too large
(Err42) with P9-47
Ten’s
:
Motor overspeed (Err43) with P9-
47
Hundred’s
:
Initial position error (Err51)
Same as P9-47
Thousand’s
:
Speed feedback error
(Err52) with P9-47
00000
〇
P9-54
Continue to run
frequency selection
when fault occurs
0: Run at the current operating frequency
1: run at the set frequency
2: Run at the upper limit frequency
3: Run at the following frequency limit
4: Run at abnormal standby frequency
0
〇
P9-55
Abnormal backup
frequency
60.0%
~
100.0%
(
100.0% correspond Maximum
frequencyP0-10
)
100.0%
〇
P9-56
Motor temperature
sensor type
0
:
No temperature sensor
1
:
PT100
2
:
PT1000
0
〇
P9-57
Motor overheat
protection threshold
0
℃~
200
℃
110
℃
〇