72
P/N 133487
Banner Engineering Corp.
•
Minneapolis, U .S .A .
www .bannerengineering .com • Tel: 763 .544 .3164
SC22-3 Safety Controller
Instruction Manual
Troubleshooting and Maintenance
Figure 8-6. Fault Log screens — OBI
8.6.2 View Fault Log — OBI
The Safety Controller keeps a record of the last ten faults that
have occurred . The faults are viewable from the View Fault
Log menu . To view the fault log, select View Fault Log in the
Diagnostics menu and press OK .
The screen shows the first fault stored in the fault log . Use the
left/right arrow keys to view additional faults in the fault log .
• The top line of the fault log screen indicates which device had
the fault .
• The second and third lines provide a brief description of the
fault .
• The fourth line displays how long ago the fault occurred . For
instance, a time of 01:30:23 indicates the fault occurred one
hour, thirty minutes, and 23 seconds previous to the View Fault
Log menu’s appearance on the screen . (If a fault is added
to the fault log while the fault log is being viewed, the time
is displayed as New Fault . If a fault is older than twenty-four
hours, the time is displayed as > 24hours .)
• The fifth line provides the fault code . Use the fault code and
information in Section 8 .3 .1 to obtain more information about the
fault and additional suggestions for correcting it .
NOTE: Removing power from the Safety Controller will clear the
fault log, in addition to the method described next .
Device Name
Fault
Description
Time Since
Fault
Fault Code
8.6.3 Clear Fault Log — OBI
To clear the fault log, select Clear Fault from the Diagnostics
menu (see Figure 8-7) and press OK .
Figure 8-7. Clearing the fault log — OBI
When the fault is cleared, press OK to return to the Fault
Diagnostics menu, then press ESC twice to return to the Run
mode menu .
Figure 8-8. Fault log is cleared — OBI