![Banner SC22-3 Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/banner/sc22-3/sc22-3_instruction-manual_471844118.webp)
116
P/N 133487
Banner Engineering Corp.
•
Minneapolis, U .S .A .
www .bannerengineering .com • Tel: 763 .544 .3164
SC22-3 Safety Controller
Instruction Manual
Appendix C
Adding Other Input Devices
The steps required to add other input devices are similar to
those you’ve just completed .
Now create the following input devices, with properties as
provided in the steps below:
• Gate Switch, GS01
• Two Hand Control, THC01
• Reset Input, RS01
• Optical Sensor, OS01
• External Device Monitors; EDM01, EDM02, and EDM03
• Mute Sensor Pair, M1+M2
Safety Input: Gate Switch – GS01
Circuit Type:
Single-Channel,
2-Terminal Contact Switch
Terminals: S5 and S6
Mapped to: SO1, SO2
Automatic Reset Logic
Safety Input: Two-Hand Control – THC01
Circuit Type:
2X complementary,
PNP switch
Terminals:
S7, S8, S9, and S10
Mapped to: SO3
Non-Safety Input: Reset Input – RS01
Circuit Type:
Single Channel,
2-Terminal Contact Switch
Terminals: S21 and S22
Mapped to:
SO1, SO2, and SO3
Safety Input: Optical Sensor – OS01
Circuit Type:
Dual-Channel, PNP
Terminals: S11and S12
Mapped to: SO1and SO2
Automatic Reset Logic
Safety Input: Mute Sensor – M1 + M2
The next input is a little different than the previous inputs
added . So, we’ll discuss this one in a little more detail .
After selecting to add a mute sensor and entering its
name, set the circuit type and the terminal assignments
as follows:
Circuit Type:
Dual-Channel Contact Switch
Terminals: 13, 14, 15 and
16
Instead of mapping to an output, mute sensor inputs are
mapped to the inputs they will mute . Only certain types of input
devices can be muted . The Safety Controller creates a list of the