P/N 133487
53
Banner Engineering Corp.
•
Minneapolis, U .S .A .
www .bannerengineering .com • Tel: 763 .544 .3164
SC22-3 Safety Controller
Instruction Manual
Configuration — Onboard Interface
Configure Input Device Properties
For each input device, the following parameters must be
configured:
• Name (or use the auto-generated default name)
• Circuit type
• Terminal assignments (or use the auto-generated terminal
assignments)
• Reset logic (for some devices)
• Output mapping or input mapping (depending on device)
Enter Input Device Name — The Enter Name menu is
displayed . A default name automatically appears, but the device
may be renamed (up to 10 characters) .
• Use the left/right arrows to select the character position .
• Use the up/down arrows to select the character for each
position (choices A-Z, 0-9, -, +, or space) .
• When the screen (as shown below) shows the correct device
name, press OK .
Input Properties Menu — The Input Properties menu is used
to:
• Select the input device’s circuit type
• Edit the terminal assignments, if needed
• Select the output(s) (or input), the input will control
• Select between automatic and manual reset logic
(depending on device)
←
O
K
ES
C
→
Safety Input
(Section 5.5.1)
Non-Safety
Input
(Section 5.5.2)
←
O
K
ES
C
→
←
O
K
ES
C
→
M
ut
e
En
ab
le
Re
se
t
O
N/
O
FF
G
at
e
Sw
itc
h
O
pt
ic
al
Se
ns
or
E-
St
op
Sa
fe
ty
M
at
Pr
ot
ec
tiv
e
St
op
Tw
o-
Ha
nd
Co
nt
ro
l
En
ab
lin
g
De
vi
ce
Ro
pe
Pu
ll
ED
M
By
pa
ss
Sw
itc
h
M
ut
e
Se
ns
or
Add Input
(Section 5.5)
Add an Input continued
Select the Circuit Type of the Input — Use the up/down
arrows to select Select Circuit Type, and press OK .
NOTE: See Appendix A for more information about safety circuit
integrity levels and the capabilities of each circuit type .
• The Select Circuit Type menu appears .
• Use the left/right arrows to select the desired circuit type (a
dual-channel, 4-terminal circuit type is shown below) for the
input device and press OK .
• After the circuit type is selected, the display returns to the
Input Properties menu .
Edit the Terminal Assignments — When the input circuit type
is selected, the Safety Controller automatically assigns the next
available terminals for the input device . To view and change
these terminal assignments, select Edit Terminals, and
press OK .
• Use the left/right arrow buttons to select the terminal
assignment to be changed .
• Use the up/down arrows to change the terminal assignment .
• When the terminal assignments are as desired, press OK .
NOTE: Only unassigned terminals can be assigned .
(Exception: Terminals used for a specific input device can be
assigned twice during the edit process, if the same terminals
will be used, in a different order, for this specific device .)
• After the terminal assignments are approved, the display
returns to the Input Properties menu .