![Banner SC22-3 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/banner/sc22-3/sc22-3_instruction-manual_471844102.webp)
100
P/N 133487
Banner Engineering Corp.
•
Minneapolis, U .S .A .
www .bannerengineering .com • Tel: 763 .544 .3164
SC22-3 Safety Controller
Instruction Manual
Appendix A
Power
2-Hand Inputs
Mute Enable
Mute Sensor 1
Mute Sensor 2
Backdoor Timer
Safety Output
Max.
Time
Max.
Time
Max.
Time
Max.
Time
Mute cycle prevented
due to open Mute
Enable input
Mute cycle prevented
due to open Mute
Enable input
< 3s
< 3s
< 3s
< 3s
A.11.9 Mute Timing Sequences, continued
Figure A-11. Mute timing diagram with two mute sensors, mute enable, two-hand control and limited mute time.