User and Programming Manual
20 XDS
Series
2.10 Factory Configuration Options
All XDS models can be factory configured with the options shown below. Configuration changes
can be made in the field if needed. Refer to Chapter 5 for details on changing configuration
settings.
Option
Configuration
none
Stand-alone and Master operation.
-AUX
Auxiliary configuration. Can be used with Master XDS unit to increase
power level.
-RPV10
Stand-alone operation with analog voltage programming, 0 – 10 V.
-RPV5
Stand-alone operation with analog voltage programming, 0 – 5 V.
-RPC10
Stand-alone operation with analog current limit programming, 0 – 10 V.
-RPC5
Stand-alone operation with analog current limit programming, 0 – 5 V.
2.11 -LC Option
The –LC option reduces the output capacitance of each DC power module. This results in
improved rise and fall times compared to a standard XDS unit. The output noise and ripple
specification is increased by a factor of 2 when adding the –LC option. This option is available
only on models with voltage ranges of 100V and below. The –LC option must be ordered at time
of initial orders. This option cannot be retrofitted.
-LC Option
Output capacitance with LC option
Capacitance per 5 KW module.
Standard Unit
Capacitance per 5 KW module.
30V 11200 uF
44000 uF
40V 7800 uF
30000 uF
50V 7800 uF
24000 uF
80V 3000 uF
7800 uF
100V 940 uF
4400 uF
Note: -LC option is available only on 30V, 40V, 50V, 80V and 100V output voltage range models.
Содержание XDS 100-100
Страница 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Страница 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Страница 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Страница 45: ...User and Programming Manual XDS Series 45 Figure 6 1 DC Power Supply Block Diagram IF option shown ...
Страница 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...