User and Programming Manual
104
XDS
Series
11.7.6 *RST
This command resets the power supply to a setting defined by the values in the register defined by
PON if valid or by the following factory-defined states:
Note:
When using the *RST command, allow a 100 msec delay in your program for
the XDS supply to complete the reset procedure before sending subsequent
bus commands.
Table 11-5: *RST Default Parameter Values
Item
Value
Item
Value
VOLT
0.0 V
VOLT HIGH
Max. available
VOLT
LOW
0
CURR
Max. available
CURR HIGH
Max. available
CURR
LOW
0
OUTP
0 (OFF)
DISP:MODE
1 (CURRENT)
Command Syntax
*RST
Parameters None
Related Commands
*SAV
Table 11-6: Status Registers - Power on Conditions
Register
Status on Power On
Status after *RST
- ESE register
All 0’s
All 0’s
- ESR register
PON bit = 1, all others 0
PON = 0, all others unaffected
- STB register
All 0’s
All 0’s
- SRE register
All 0’s
All 0’s