User and Programming Manual
XDS Series
99
SYSTem:LOCal
This command sets the interface in Local state, which enables the front panel controls. This
command only applies to the RS232C interface. If IEEE 488 is used, the remote/local state is
determined by the REN line on the IEEE 488 interface but the SYST:LOC and SYST:REM command
will also be accepted and will toggle the remote state despite the status of the IEEE REN line.
Command Syntax
SYSTem:LOCal
Parameters None
Example SYST:LOC
Related Commands
SYST:REM
SYSTem:REMote
This command sets the interface in the Remote state, which disables all front panel controls. This
command only applies to the RS232C interface. If IEEE 488 is used, the remote/local status is
determined by the REN line on the IEEE 488 interface but the SYST:LOC and SYST:REM command
will also be accepted and will toggle the remote state despite the status of the IEEE REN line.
Command Syntax
SYSTem:REMote
Parameters None
Example SYST:REM
Related Commands
SYST:LOC
SYSTem:PON
This command is used to define the register value the power supply will use to initialize its
parameters at power up. If data in the selected register is not valid or the selected register is 8, the
initialization will be with factory default values. Refer to Table 4-1: Factory Default Power on Settings
on page 33.
Command Syntax
SYSTem:PON <NRf>
Parameters
0 to 8
Examples SYST:PON
1
Query Syntax
SYST:PON?
Returned Parameters
<NR1>
Related Commands
*RST
Содержание XDS 100-100
Страница 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Страница 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Страница 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Страница 45: ...User and Programming Manual XDS Series 45 Figure 6 1 DC Power Supply Block Diagram IF option shown ...
Страница 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...