User and Programming Manual
108
XDS
Series
where <n> is the current limit in amperes.
If the load attempts to draw more current than the programmed limit, the power supply switches to a
constant current mode and will reduce the output voltage as required.
The maximum current that the Power supply can output is limited by model configuration and the
user set current limits. These values are defined by the LIMIT subsystem and the CURR:HIGH and
CURR:LOW commands
12.3 Making Measurements
The source has the capability to return current, peak current, power and voltage measurements.
Voltage Measurement
To measure the voltage, use:
OUTP 1
/* Close output if it was not closed already.
MEAS:VOLT?
Current Measurements
To measure the RMS current, use:
MEAS:CURR?
To measure the peak current, use:
MEAS:CURR:AMPL:RES
/* resets track and hold for peak curr. meas.
/* It may be need to turn the output on or program
/* as specific voltage at this time before taking a
/* peak current reading.
MEAS:CURR:AMPL:MAX?
/* retrieves peak current reading.
Power Measurements
To measure the power, use:
MEAS:POW?
Содержание XDS 100-100
Страница 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Страница 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Страница 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Страница 45: ...User and Programming Manual XDS Series 45 Figure 6 1 DC Power Supply Block Diagram IF option shown ...
Страница 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...