User and Programming Manual
XDS Series
37
5 Model
Configurations
5.1 Available
Configurations
The XDS controller can be reconfigured for various modes of operation. Generally, the mode of
operation is factory set at the time of shipment and is indicated on the model number tag by a
configuration option suffix. The following configurations are available.
Configuration
Configuration
Option Suffix
Description
Master
None
Normal mode of operation. A single XDS unit in
either 5, 10 or 15 KW power configuration. Both
voltage and current limit are controlled from the
front panel or over the bus.
Auxiliary
-AUX
Set to operate as an auxiliary unit to another XDS
master unit. This allows parallel operation of up to
5 identical XDS units for higher power systems.
The master unit controls auxiliary units. Voltage
and current cannot be set from the front panel or
over the bus. Measurements are still available
however.
Master, remote
programming, Voltage
-RPV5
Stand-alone mode with voltage controlled by
external analog DC voltage input signal. Full-scale
voltage required 5 VDC input. Current limit can be
set from the front panel or over the bus.
Master, remote
programming, Voltage
-RPV10
Stand-alone mode with voltage controlled by
external analog DC voltage input signal. Full-scale
voltage required 10 VDC input. Current limit can be
set from the front panel or over the bus.
Master, remote
programming, Current
-RPC5
Stand-alone mode with current limit controlled by
external analog DC voltage input signal. Full-scale
voltage required 5 VDC input. Voltage can be set
from the front panel or over the bus.
Master, remote
programming, Current
-RPC10
Stand-alone mode with current limit controlled by
external analog DC voltage input signal. Full-scale
voltage required 10 VDC input. Voltage can be set
from the front panel or over the bus.
Table 5-1: XDS Controller Configuration Options
Содержание XDS 100-100
Страница 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Страница 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Страница 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Страница 45: ...User and Programming Manual XDS Series 45 Figure 6 1 DC Power Supply Block Diagram IF option shown ...
Страница 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...