Appendix C: Error Messages
Error Number
Error Message String
Error Causes
0
"No error"
-100
"Command error"
Generally the result of sending a
command that uses incorrect syntax.
-200
"Execution error"
Generally the result of sending a value
that is out of range, i.e., a VOLT 200
command when the voltage range is only
150 V. Alternatively, programmed voltage
or current may be outside of user set
high and low programming limits.
-300
"Device specific error"
This error can have several causes, all
them hardware related. Possible causes
are:
1) AC input over voltage, under
voltage or missing input phase.
2) Over temperature condition.
3) Sense connection reversed or
shorted.
-350
"Queue overflow"
Generally caused by too many errors
being generated without reading error
status, causing error buffer to overflow.
-400
"Query error"
Generally caused by sending a query
followed by another command without
accepting the query response first.
Table 13-1: Bus Error Messages