and PIN 2 of the ABS control unit: if NOT OK, replace the vehicle wiring harness, if OK,
check the continuity between PIN 2 of the inertial platform (Sensor box) and PIN 11 of the
ABS control unit; if NOT OK, replace the wiring harness, if OK, check the correct power
supply to PIN 4 (12V) and the grounding of ABS control unit PIN 1: if NOT OK, restore the
wiring harness, if OK, replace the inertial platform (sensor box)
•
Configuration error - Open the diagnostic tool devices status page to check if the control unit
setting is actually consistent with the motorcycle setting. Example: if the vehicle is equipped
with inertia sensor platform (Sensor box), the correct status we should find on the diagnostic
tool devices status page will be: Aprilia Traction Control Performance (in a bend) PRESENT.
While on a vehicle equipped with inertia sensor platform (Sensor box) and diagnostic tool
indication: Aprilia Traction Control Performance (in a bend) NOT PRESENT update the
control unit
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
U1121 Diagnosis of "ABS control unit" CAN line or CLF frame counter
Functional diagnosis:
•
Signal absent
Error cause:
•
If there is no signal, no signal is received from the ABS control unit.
This error is indicated by lighting up in a fixed manner the MI warning light.
Troubleshooting:
•
Missing signal - Perform the check procedure for pin 2 and 11 of the ABS control unit con-
nector, for pin 66 and 80 of the Marelli control unit vehicle connector: if NOT OK, restore; if
OK with key OFF, disconnect the ABS control unit connector; if NOT OK replace the wiring
harness, if OK check the correct power supply to PIN 18 (12V) and the grounding of ABS
control unit PIN 1; if NOT OK, restore the wiring harness, if OK, replace the ABS control unit.
NOTE
THE PRESENCE OF THIS ERROR DETERMINE THE DEACTIVATION OF THE TRACTION CON-
TROL AND THE CRUISE CONTROL.
P1800 Rear wheel radius learning diagnosis
Functional diagnosis:
•
CAN error while learning / Signal not plausible.
Error cause:
•
In case of CAN error during acquisition, system warns that the procedure can not be com-
pleted due to a communication problem on the CAN line.
RSV4 1100 Factory
Electrical system
ELE SYS - 237
Содержание RSV4 1100 Factory
Страница 1: ...SERVICE STATION MANUAL 2Q000401 RSV4 1100 Factory ...
Страница 4: ......
Страница 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 55: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Страница 63: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 89: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 245: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 270: ...INDEX OF TOPICS ENGINE ENG ...
Страница 384: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Страница 387: ... Remove the fuel pump Injection RSV4 1100 Factory Power supply P SUPP 387 ...
Страница 393: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 417: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 455: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 457: ...Operating diagram ABS functional diagram key RSV4 1100 Factory Braking system BRAK SYS 457 ...
Страница 488: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Страница 499: ...INDEX OF TOPICS BODYWORK BODYW ...
Страница 540: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Страница 546: ... Fit the two seater saddle Pre delivery RSV4 1100 Factory PRE DE 546 ...