Hydro Cat 5015B
Service Manual
SWEEP SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
BROOM MOTOR - CARBON BRUSH INSPECTION
The carbon brushes in the sweeping broom motor should be inspected once a year.
To inspect the brushes . . .
1
Disconnect the battery cables and remove the battery and the battery tray from the machine.
2
Remove the brush cover from the brush motor and remove the carbon brushes. Replace the carbon
brushes if they are worn to a length of 3/8 inch (10 mm) or less.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
BROOM MOTOR REMOVAL / REPLACEMENT
To remove or replace the broom motor . . .
1
Disconnect the battery cables and remove the battery and the battery tray from the machine.
2
See Figure 6. Open the left side access door and loosen the (2) “K” bolts.
FIGURE 6 HERE
FIGURE 6
O
M
L
K
N
P
Q
1"
Front
3
Loosen the (2) “L” locknuts and loosen
the belt by turning the (2) “M” bolts.
4
Remove the belt tension spring “N” and
remove the belt from the motor pulley.
5
Disconnect the broom motor leads.
6
Remove the (4) “O” motor mount bolts
and lift the motor out of the machine.
Note: When installing the broom motor, push
it up to the top of the mounting slots
before tightening the mounting bolts.
7
Follow the steps above in reverse order to
re-assemble.
8
Adjust the belt tension so that there is a 1
inch (2.57 cm) space at the idler pulley as
shown in Figure 6.
78