![Advance acoustic HydroCat 459020 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/advance-acoustic/hydrocat-459020/hydrocat-459020_service-manual_2855521018.webp)
Hydro Cat 5015B
Service Manual
SOLUTION SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
SOLUTION SYSTEM MAINTENANCE
The solution system should be flushed every 15 hours of operation to prevent a build-up of soap residue in the
solution valves. To flush the system...
1
Park the machine outdoors or near a floor drain and open the solution tank drain valve.
2
When the tank is empty, close the drain valve and put about 6 inches (15 cm) of clean, warm water in the
tank.
3
Reach under the front of the machine and open the (2) flow control valves all the way.
4
Turn the key switch ON and put the scrub brush switch in the ON (I) position. When the brushes are all
the way down , turn the key switch OFF.
5
Push the solution lever (on the control panel) forward, to the full-on position. Allow all of the warm water
to drain through the valves.
6
Return the flow control valves to their original position.
Note:
See the
Hydro-Max II
chapter for additional maintenance on machines equipped with this option.
15