Hydro Cat 5015B
Service Manual
SOLUTION SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
TROUBLESHOOTING
Follow the instructions under the “Problem” that best describes the condition of the machine being serviced.
Also see the
Hydro-Max II
chapter for additional solution system troubleshooting information.
Before Troubleshooting, make sure that there is at least 6 inches of water in the solution tank and the solution
lever is pushed all the way forward, to the maximum ON position.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Problem: Solution Leaks With Control Lever in OFF Position
1
Replace solution valve.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Problem: Little or No Solution to Scrub Brushes
1
Check the adjustment of the (2) flow control valves.
2
Check filter screen at bottom of solution tank.
3
Check linkage between solution lever and main solution valve.
4
Check main solution valve to see if the ball inside the valve moves along with the lever on the side of the
valve.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Problem: Uneven Solution Flow
1
Check the adjustment of the (2) flow control valves.
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Problem: Solution Lever Stuck in OFF Position
1
Lower scrub brushes - solution lever cannot be pushed forward with the brushes in the UP position.
19