SCRUB BRUSH SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
BRUSH DRIVE GEAR CASE - OIL CHECK
Check the oil level in the brush drive gear cases once each year or when there is evidence of oil leakage.
To check the oil level...
1
Turn the key switch ON and put the brush switch in the ON (O) position. When the brushes are all the
way down, turn the key switch OFF.
2
Remove the (2) lower corner panels from front of the machine.
3
See Figure 4. Remove the “W” oil plug from the top of each gear box and measure the oil level. The
maximum oil level is 1-1/2 inches (3.8 cm) from the top of the gear case. If the oil is more than 1-3/4
inches (4.5 cm) from the top of the gear case, add 140W gear lube.