Gen II
User Manual
7-26 – Main Rotor Track & Balance
Chapter 7
Revision 3.00, Apr 2020
7.2.6.
– Review Prior Runs Data
The “Review Prior Runs Data” screen will now appear presenting the Vibration data and Track
data for the current run and condition.
The data will be displayed in the order of the current run and first condition measured. From this
first screen, press the [
] key to proceed to the next condition measured for the current run.
Press the [
] key to return to the previous condition.
If the current run is number two or greater, pressing the [
] key will move to the same condition
as on the previous run. Press the [
] key to return to the current run. Always observe the run
number and condition name at top of the screen to identify the data you are viewing.
This screen also offers a chance to retake the measurements.
Press the [F1] “Retake All” to retake the measurements Vibration data and Track data.
Press the [F2] “Retake Vib” to restart the measurements for Vibration only.
Press the [F3] “Retake Trk” to restart the measurements for Track only.
When you have finished reviewing the data, press [OK]. You will be returned to the “Select
Conditions” screen to shown in paragraph 7.2.5..
Continue collecting data for all Conditions if possible. If during the current run, the [F2]
“Adjust” key becomes visible, the analyzer has collected enough information to present a
solution. If needed, shut down aircraft to make adjustments prior to continuing to collect data for
the remainder of conditions.