Chapter 25
Specifications
(Revision 4.10, Jan 2020)
Physical
Dimensions:
9.75” H x 10.5” W x 5.0” D (24.77 cm x 26.67 cm x 12.7 cm)
Weight:
6.0 lbs. (2.72 kg.)
Power Requirements:
Smart Li-Ion Battery (Internal), 87 Wh
Operating Time:
8.0 Hours
Charging Time:
3.0 Hours (approximately)
Memory
1 GB Flash
Inputs
Viper II
Cobra II
Vibration Channels:
4 ea.
2 ea.
Tach / Mag Pickup:
4 ea.
2 ea.
TraX Optical Tracker
1 ea.
1 ea.
Strobe
1 ea.
1 ea.
USB Port:
2 ea.
2 ea.
Measurements
Phase Accuracy:
<1°
<1°
Balance Frequency:
60-60,000 RPM, ± 0.002%
60-10,000 RPM, ± 0.2%
Vibration Freq Range:
0-30 kHz
0-30 kHz
Vibration Amplitude:
0-240 IPS (peak), 20 mV / IPS
0-240 IPS (peak), 20 mV / IPS
Dynamic Range:
98 dB
98 dB
Environmental
Operating Temperature:
-4° to 120° F (-20° to +49°C)
Relative Humidity:
10-85% (non-condensing)
AC Input:
The data acquisition system is capable of measuring AC values to 9.5V Peak-
Peak.
Sensor Types:
The analyzer will accept any vibration signal input (acceleration, velocity, or
displacement.) The input is then displayed as collected or integrated to any other
vibration unit. The vibration input will accept any voltage - generating sensor
(must have external charge converter when in charge mode) and will supply
power to the sensor when required. The Cobra II only accepts acceleration or
velocity inputs.
Analysis Range:
Anti-aliasing filters are used with a Fast Fourier Transform (FFT) to accurately
transform data from the time to the frequency domain. The analyzer will perform
FFT resolutions of 100, 200, 400, 800, 1600, and 3200 lines.