15-19 – Overall Vibration Survey
Chapter 15
Revision 4.10, Apr 20
“Restart” respectively. If you wish to Expand the X scale even further, retrace the steps
from that point as described in the text.
Pressing the [F2] “Default” key will return the X or Y scale to the values specified in the
setup. This is a quick and easy way to return all expanded and shrunken scales to that
default value without the necessity of numerous keystrokes. If the scale is already at the
setup values when the [F2] Default key is pressed, the boxes above the [F1], [F2], [F4]
and [F5] keys will return to “Maximum,” “Pause,” “Overall,” and “Restart” respectively.
No other changes will occur.
Pressing the [F3] “Shrink” key will lower the X or Y scale of the spectra, in effect
shrinking the viewing area. You might think of this function as a “Zoom In” feature. If
the view is already at the minimum of the specified scale range, no scaling change will
occur. However, the cursor will be displayed and the X, Y, and “Ovr” (Overall) values
will be shown in the upper right corner of the screen. The boxes above the [F1], [F2],
[F4] and [F5] keys will return to “Maximum,” “Pause,” “Overall,” and “Restart”
respectively. If you wish to Shrink the X scale even further, retrace the steps from that
point as described in the text.
Pressing the [F4] “View” key will display another sub menu. The Function keys will be
identified by the descriptions assigned in paragraph 15.1.1.1.9 above with the [F5] key
being labeled “All”. Pressing the “F” key below the name of the channel will enlarge the
display of that plot to the full size of the screen. The other plots will continue to gather
data they will just be hidden from view. Pressing [F1] “Options”, [F3] “View”, and [F5]
“All” will return all available plots to the screen. The boxes above the [F1], [F2], [F4]
and [F5] keys will return to “Maximum,” “Pause,” “Overall,” and “Restart” respectively.
Pressing the [F5] “Cancel” key will cancel the selection and return the “F” keys to
“Maximum,” “Pause,” “Overall,” and “Restart” respectively.
15.1.8.4.2.
Pressing the [F2] “Pause” key will pause data acquisition. Once pressed, the menu will
change to “Resume” allowing the user to resume data collection. Pressing “Resume” will
resume data collection.
15.1.8.4.3.
Pressing [F4] “Overall” will cause the screen to change from the spectra plot to the
overall display as described in paragraph 15.1.8.1 above. You can change back to the
spectra plot by pressing [F4] “Spectra”.
15.1.8.4.4.
Pressing [F5] “Restart” will restart data acquisition. Once pressed, all data collected up to
that point will be lost and data acquisition will begin again.
15.1.9.
– Storing Data
Anytime during the job, you may press [OK] to terminate data acquisition. The analyzer then
displays the screen shown below giving you the opportunity to store the collected data. Pressing